ELECTRICAL CHARACTERISTICS "REED" SWITCH Sensor type REED 2 wires Supply voltage 3÷30 Vac/dc Electrical contact NO Normally open Switching current 0,2 AMPS Power rating(Ohmic load) 6 W Working temperature -10°C/+70°C (14°F/158°F) Protection degree IP67 -
Thermoplastic level gauges made of transparent polyamide with good mechanical resistance, are compatible with mineral oil, gasoline, lubricant, petroleum, solvents and most chemical agents. Avoid contact with alcohol-based solutions and high-temperature antifreeze. For this type of application, use the special model/CX which is made of special resin resistant to fluids containing alcohol and antifreeze.
External plastic protection made of PA66 30% fiberglass.
The internal body of the level gauges consists of two transparent parts assembled and then sealed using an ultrasonic welding process, to ensure a leak-free seal around the body. Inside the transparent body there is a graduated white sticker made of "Vinile Cast" to improve the view of the level.
M12 zinc plated bolts and flanged nuts are standard (optional AISI 303 stainless steel bolts and nuts available, Buna 70 durometer flat gasket; maximum recommended tightening torque = 5Nm ( 3.7ft lbs).
Mounting can be done externally by providing 2 M12 threaded holes at 127mm (tolerance ± 0.2mm); alternatively, they can be secured internally through 2 smooth holes Ø 12.5 mm (-0.2) using the flange nuts.
Maximum working temperature 80°C (176°F). Maximum working pressure 1 bar (14.7 PSI), (if used in pressurized tanks, contact our technical office).
The REED switch sensor is connected to the internal transparent tube, adjustable in height according to the level control requirements; sensor is supplied with power cable (length 30 cm / 0.98 ft) and M8 male connector; on request it is possible to provide a separate connection cable (length 250 cm / 8.2 ft) complete with M8 female connector.
Floating element made of technopolymer containing a magnetic element that closes the electrical contact when it reaches the "REED" level switch sensor.
Standard executions: with electrical contact normally open.
Operation characteristics: the XL127-PLAST-SL vertical level gauge, in addition to allowing a visual inspection, provides an electrical signal when the floating element reaches the minimum preset level, after closing the electrical circuit.
Data Sheet (PDF) -
ELECTRICAL CHARACTERISTICS MAX TEMPERATURE ELECTRICAL SENSOR Power supply AC/DC Electrical contact NO Normally open
NC Normally closedTensión máxima aplicable 250 Vac 10A Protection degree IP65 Calibration 60°C/140°F - 70°C/158°F Precisión ± 5°C (data referred to a room temp. = 20°C/68°F) -
Thermoplastic level gauges made of transparent polyamide with good mechanical resistance are compatible with mineral oil, gasoline, lubricant, petroleum, solvents and most chemical agents; Avoid contact with alcohol-based solutions and high-temperature antifreeze. For this type of application, use the special model/CX which is made of special resin resistant to fluids containing alcohol and antifreeze.
External plastic protection made of PA66 30% fiberglass.
The internal body of the level gauges consists of two transparent parts assembled and then sealed using an ultrasonic welding process, to ensure a leak-free seal around the body. Inside the transparent body there is a white aluminum screen to improve the view of the level.
M12 zinc plated bolts and flanged nuts are standard (optional AISI 303 stainless steel bolts and nuts available, Buna 70 durometer flat gasket; maximum tightening torque recommended = 5Nm (3.7ft lbs).
Mounting can be done externally by providing 2 M12 threaded holes at 127mm (tolerance ± 0.2mm); alternatively, they can be secured internally through 2 smooth holes Ø 12.5 mm (-0.2) using the flange nuts.
Maximum working temperature 80°C (176°F). Maximum working pressure 1 bar (14.7 PSI), (if used in pressurized tanks, contact our technical office).
Maximum temperature electrical sensor (calibrated at 60°C-70°C / 140-158°F) incorporated in the galvanized M12 bolt (IP65 protection degree) with DIN rotary connector.
Standard executions: XL/127-PLAST-ST-NO (normally open electrical contact) - XL/127-PLAST-ST-NC (normally closed electrical contact).< br> Operation characteristics: the vertical level indicator XL / 127- PLAST-ST, in addition to allowing a visual inspection, provides an electrical signal when the required temperature of the fluid inside the tank is reached (under normal use conditions). room temperature of about 20°C/68°F); in the XL / 127-PLAST -ST-NO model the electric circuit closes once the specified temperature is reached, in the XL / 127-PLAST -ST-NC model the electric circuit opens when the specified temperature is reached.
Data Sheet (PDF)
DOWNLOAD 3D CAD -
ELECTRICAL CHARACTERISTICS "REED" SWITCH Sensor type REED 2 cables Supply voltage 3÷30 Vac/dc Electrical contact NO Normally open Switching current 0,2 AMPS Power rating(Ohmic load) 6 W Working temperature -10°C/+70°C (14°F/158°F) ELECTRICAL CHARACTERISTICS MAX TEMPERATURE ELECTRICAL SENSOR Sensor type Bimetal contact Power supply AC/DC Electrical contact NO Normally open
NC Normally closedTensión máxima aplicable 250 Vac 10A Protection degree IP65 Calibration 60°C/140 F - 70°C/158°F Accuracy ± 5°C (data referred to a room temp. = 20°C/68°F) -
Thermoplastic level gauges made of transparent polyamide with good mechanical resistance are compatible with mineral oil, gasoline, lubricant, petroleum, solvents and most chemical agents; Avoid contact with alcohol-based solutions and high-temperature antifreeze. For these types of applications, use our model/CX, which is made of special resin resistant to fluids containing alcohol and antifreeze.
External plastic protection made of PA66 30% fiberglass.
The internal body of the level gauges consists of two transparent parts assembled and then sealed using an ultrasonic welding process, to ensure a leak-free seal around the body. Inside the transparent body there is a graduated white sticker made of "Vinile Cast" to improve the view of the level.
M12 zinc plated bolts and flanged nuts are standard (optional AISI 303 stainless steel bolts and nuts available, 70 durometer Buna flat gasket; maximum recommended tightening torque = 5 Nm (3.7 lb-ft).
Mounting can be done externally by providing 2 M12 threaded holes at 127mm (tolerance ± 0.2mm); alternatively, they can be secured internally through 2 smooth holes Ø 12.5 mm (-0.2) using the flange nuts.
Maximum working temperature 80°C (176°F).
Maximum working pressure 1 bar (14.7 PSI), (if used in pressurized tanks, contact our technical office).
The REED switch sensor is connected to the internal transparent tube, adjustable in height according to the level control requirements; sensor is supplied with power cable (length 30 cm / 0.98 ft) and M8 male connector; On request, it is possible to provide a separate connection cable (length 250 cm / 8.2 ft) complete with M8 female connector.
Floating element made of technopolymer containing a magnetic element that closes the electrical contact when it reaches the "REED" level switch sensor.
Maximum temperature electrical sensor (calibrated at 60°C-70°C / 140-158°F) incorporated in the galvanized M12 bolt (IP65 protection degree) with DIN rotary connector.
Standard executions: XL127-PLAST-SL-ST-NO (electrical contact normally open on the temperature sensor) XL127-PLAST-SL-ST-NC (electrical contact normally closed on temperature sensor).
Operation characteristics: the vertical level indicator XL127- PLAST-SL-ST, in addition to allowing a visual inspection, provides an electrical signal when the required temperature of the fluid inside the tank is reached (under normal use conditions). ambient temperature of approximately 20°C/68°F, and also provides an electrical signal when the floating element reaches the preset minimum level.
XL127-PLAST-SL-ST-NO: the level sensor closes the electrical circuit when the preset minimum level is reached; The maximum temperature sensor closes the electrical circuit at the preset threshold temperature.
XL127-PLAST-SL-ST-NC: the level sensor closes the electrical circuit when it reaches the minimum preset level; The maximum temperature sensor opens the circuit at the preset threshold temperature.
Data Sheet (PDF)
DOWNLOAD 3D CAD -
ELECTRICAL CHARACTERISTICS "REED" SWITCH Sensor type REED 2 wires Supply voltage 3÷30 Vac/dc Electrical contact NO Normally open Switching current 0,2 AMPS Power rating(Ohmic load) 6 W Working temperature -10°C/+70°C (14°F/158°F) Protection degree IP67 -
Vertical level gauges with external aluminum shield, standard center-to-center distance 300-400-500 mm; consult our technical office for custom lengths.
Black polyamide PA 66 end caps, transparent polycarbonate tube; Behind the tube is a graduated contrast screen for a visual check of the liquid level.
Aluminum shield can be rotated 90 degrees when needed for side view.
Zinc plated M12 bolts and nuts (available on request in AISI 303 stainless steel), Buna flat gasket with 70 durometer; Suggested maximum tightening torque = 5 Nm (3.7 lb-ft).
Suggested for applications with mineral oils, hydraulic fluids, diesel and fluids containing glycols. Avoid contact with gasoline, hydrocarbons and solvents (contact our technical office for compatibility with other chemical agents).
Mounting can be done externally by providing 2 M12 threaded holes at center to center distance (tolerance ± 0.5mm) or internally secured via 2 smooth holes Ø 12.5mm (-0.2 ), using the flanged nuts.
Maximum working temperature 80°C / 176°F (with hydraulic fluid), maximum suggested pressure 1 bar / 14.5 PSI (for use on pressure tanks, contact our technical office).
The REED switch sensor is connected to the internal transparent tube, adjustable in height according to the customer's level requirements; Minimum budget placed about 50 mm from the center of the lower bolt. The sensor is supplied with power cable (length 30 cm / 0.98 ft) and M8 male connector; On request, it is possible to provide a separate connection cable (length cm 250 / 8.2 feet) complete with M8 female connector. Possibility also of applying more level sensors positioned at different heights.
Technopolymer floating element containing a magnetic element that closes the electrical contact when it reaches the REED level switch sensor. -Standard execution: with electrical contact normally open.
Operating characteristics: the XLV-SL vertical level indicator, in addition to allowing a visual inspection, provides an electrical signal when the floating element reaches the minimum preset level, after closing the electrical circuit.
Data Sheet (PDF) -
ELECTRICAL CHARACTERISTICS MAX TEMPERATURE ELECTRICAL SENSOR Sensor type Bimetal contact Power supply AC/DC Electrical contact NO Normally open
NC Normally closedTensión máxima aplicable 250 Vac 10A Protection degree IP65 Calibration 60°C/140°F - 70°C/158°F Precisión ± 5°C (data referred to a room temp. = 20°C/68°F) -
Vertical level gauges with external aluminum shield, standard center-to-center distance 300-400-500 mm; consult our technical office for custom lengths.
Black polyamide PA 66 end caps, transparent polycarbonate tube; Behind the tube is a graduated contrast screen for a visual check of the liquid level.
Aluminum shield can be rotated 90 degrees when needed for side view. Zinc plated M12 bolts and nuts (available on request in AISI 303 stainless steel), Buna flat gasket with 70 durometer; Suggested maximum tightening torque = 5 Nm (3.7 lb-ft).
Suggested for applications with mineral oils, hydraulic fluids, diesel and fluids containing glycols. Avoid contact with gasoline, hydrocarbons and solvents (contact our technical office for compatibility with other chemical agents).
Mounting can be done externally by providing 2 M12 threaded holes at center to center distance (tolerance ± 0.5mm) or internally secured via 2 smooth holes Ø 12.5mm (-0.2 ), using the flanged nuts.
Maximum working temperature 80°C/176 F (with hydraulic fluid), maximum suggested pressure 1 bar/14.5 PSI (for use on pressure tanks, contact our technical office).
Maximum temperature electrical sensor (calibrated at 60°C-70°C / 140-158°F) incorporated in the galvanized M12 bolt (IP65 protection degree) with DIN rotary connector.
Standard executions: XLV-ST-NO (electrical contact normally open), XLV-ST-NC (electrical contact normally closed).
Operation characteristics: the vertical level indicator XLV - ST, in addition to allowing a visual inspection, provides an electrical signal when the required temperature of the fluid inside the tank is reached (in conditions of use at room temperature of approximately 20°C/68°F); in the XLV -STNO model, the electrical circuit closes once it reaches the preset temperature, in the XLV -ST-NC model the electrical circuit opens once it reaches the preset temperature.
Data Sheet (PDF) -
ELECTRICAL CHARACTERISTICS "REED" SWITCH Sensor type REED 2 wires Supply voltage 3÷30 Vac/dc Electrical contact NO Normally open Switching current 0,2 AMPS Power rating(Ohmic load) 6 W Working temperature -10°C / +70°C (14°F/158°F) ELECTRICAL CHARACTERISTICS MAX TEMPERATURE ELECTRICAL SENSOR Sensor type Bimetal contact Power supply AC/DC Electrical contact NO Normally open
NC Normally closedTensión máxima aplicable 250 Vac 10A Protection degree IP65 Calibration 60°C/140 F - 70°C/158°F Accuracy ± 5°C (data referred to a room temp. = 20°C/68°F) -
Vertical level gauges with external aluminum shield, standard center-to-center distance 300-400-500 mm; consult our technical office for custom lengths.
Black polyamide PA 66 end caps, transparent polycarbonate tube; Behind the tube is a graduated contrast screen for a visual check of the liquid level.
Aluminum shield can be rotated 90 degrees when needed for side view. Zinc plated M12 bolts and nuts (available on request in AISI 303 stainless steel), Buna flat gasket with 70 durometer; Suggested maximum tightening torque = 5 Nm (3.7 lb-ft).
Suggested for applications with mineral oils, hydraulic fluids, diesel and fluids containing glycols. Avoid contact with gasoline, hydrocarbons and solvents (contact our technical office for compatibility with other chemical agents).
Mounting can be done externally by providing 2 M12 threaded holes at center to center distance (tolerance ± 0.5mm) or internally secured via 2 smooth holes Ø 12.5mm (-0.2 ), using the flanged nuts.
Maximum working temperature 80°C/176 F (with hydraulic fluid), maximum suggested pressure 1 bar/14.5 PSI (for use on pressure tanks, contact our technical office).
REED switch sensor is connected to the internal transparent tube, adjustable in height according to the level control requirements; sensor is supplied with power cable (length 30 cm / 0.98 ft) and M8 male connector; On request, it is possible to provide a separate connection cable (length 250 cm / 8.2 ft) complete with M8 female connector.
Floating element in technopolymer containing a magnetic element that closes the electrical contact when it reaches the "REED" level switch sensor.
Maximum temperature electrical sensor (calibrated at 60°C-70°C / 140-158 F) incorporated in the galvanized M12 bolt (IP65 protection degree) with DIN rotary connector.
Standard executions: XL127-PLAST-SL-ST-NO (electrical contact normally open on the temperature sensor) XL127-PLAST-SL-ST-NC (electrical contact normally closed on temperature sensor).
Operation characteristics: the vertical level indicator XL127-PLAST-SL-ST, in addition to allowing a visual inspection, provides an electrical signal when the required temperature of the fluid inside the tank is reached (in conditions of use at room temperature of approximately 20°C)°C / 68F), and also provides an electrical signal when the floating element reaches the preset minimum level.
XL127-PLAST-SL-ST-NO: the level sensor closes the electrical circuit when the preset minimum level is reached; The maximum temperature sensor closes the electrical circuit at the preset threshold temperature.
XL127-PLAST-SL-ST-NC: the level sensor closes the electrical circuit when it reaches the minimum preset level; The maximum temperature sensor opens the circuit at the preset threshold temperature.
Data Sheet (PDF)
PRODUCTS ACCESSORIES FOR HYDRAULIC SYSTEMS OIL LEVEL INDICATORS VERTICAL LEVEL GAUGES WITH ELECTRICAL SENSOR
48001712010VERTICAL LEVEL XL/127-PLAST-SL WITH MIN LEVEL ELECTRICAL SIGNAL
48001712020VERTICAL LEVEL XL/127-PLAST-ST WITH MAXIMUM TEMPERATURE SWITCH
48001712030VERTICAL LEVEL XL/127-PLAST-SL-ST WITH DOUBLE SENSOR (MIN LEVEL-MAX TEMPERATURE)
480017 XSLEXTENDED LEVEL XLV-SL WITH MIN LEVEL ELECTRICAL SIGNAL
480017 XSTEXTENDED LEVEL XLV-ST WITH MAX TEMPERATURE ELECTRICAL SIGNAL
480017 XSL-STEXTENDED LEVEL XLV-SL-ST WITH DOUBLE SENSOR (MIN LEVEL-MAX TEMPERATURE)