Code without thermometer Code with thermometer I H1 H2 F E A L CH1 CAD 48001725000 48001725100 254 286 34 M12 17 33 178 18 -
Vertical level indicators center to center distance 10” (254 mm).
Transparent inner tube made of polycarbonate (PC); suggested for application with mineral oils, hydraulic fluids, diesel and fluids containing glycols. Avoid contact with gasoline, hydrocarbons and solvents in general.
In the case of special applications or in the presence of aggressive liquids, the possibility of supplying the transparent tube made of borosilicate glass.
Maximum working temperature 90°C (194°F), maximum suggested pressure 1 bar (14.5 PSI).
External protection made of steel with a black painted finish.
Mounting of the level gauge can be done externally by providing 2 M12 threaded holes at a center distance of 254mm, tolerance ±0.2mm. Alternatively they can be secured internally through two Ø 12.5mm (-0.2) plain holes using the supplied flanged nuts. Suggested maximum tightening torque 5 Nm.
The XLT model is equipped with an internal thermometer scaled in Celsius 0-100°C and Fahrenheit 50-200F.
Possibility of mounting a maximum temperature sensor set at 60°C / 140°F - 70°C / 158°F - N.C. or not. - (see photo) that opens or closes the electrical circuit, when the established temperature threshold is reached.
Data Sheet (PDF)
PRODUCTS ACCESSORIES FOR HYDRAULIC SYSTEMS OIL LEVEL INDICATORS EXTENDED VERTICAL LEVEL GAUGES
480017-10EXTENDED VERTICAL LEVEL GAUGES XL/10-XL/10T